D3655

3

Bottom Panel Cable Connections

Load Cell Connection

The indicator operates with strain gage load cells. The system is normally

supplied with a J-BOX cable going between the scale indicator and the load cell

junction box. Extension kits are available from your dealer in various lengths.

To connect the load cells, attach the junction box cable to

the J902 connector on the bottom panel of the scale.

Connect the load cell cables to the junction box as shown

left.

WHITE

SIGNAL +

GREEN

SIGNAL -

RED

EXCITATION +

BLACK

EXCITATION -

SHIELD

SHIELD

Notes:

Follow color key on circuit board to insure proper connection

of load cell wires.

For stationary scales, a lightning protected J-Box should be

installed to prevent or lessen damage to the scale when

lightning strikes nearby. Lightning protection is not required

for mobile applications. For lightning protection installation

instructions, refer to Digi-Star form F3050.