Optional Settings
D3734-US Rev E
SW300 User’s Manual
9
OPTIONAL SETTINGS
Load Cell Setup
1. Press and hold and
at the same time until
setup
is
shown.
2. Press to advance through
selections
3. Press to save.
Description
CAP (lbs)
3300LB
StockWeigh 3300 (pounds)
4,000
6600LB
StockWeigh 6600 (pounds)
7,000
SB4 LB
StockWeigh 1250 (pounds)
10,000
I0K LB
StockWeigh 10000 (pounds)
10,000
I4K LB
StockWeigh 14000 (pounds)
15,000
3300KG
StockWeigh 3300 (kilograms)
1,999
6600KG
StockWeigh 6600 (kilograms)
2,999
SB4 KG
StockWeigh 1250 (kilograms)
5,000
I0K KG
StockWeigh 10000 (kilograms)
5,000
I4K KG
StockWeigh 14000 (kilograms)
6,999
Other
Other load cell (Use Dead Weight Cal.)
_______
1
2
3
1
3300