MENUS AND CALIBRATION


1. Press and hold for 3

seconds.

2. Press O repeatedly until

desired setting shows.

3. Press to change setting

option.

4. Press to save setting and

advance to next setting.

5. Press O repeatedly until

indicator returns to weighing mode.

SETTING

[display]

Options [displayed]

BOLD = DEFAULT

DESCRIPTION

Zero Tracking

[ZTRACK]

1-99/

OFF

Adjusts to zero for build-up of snow, mud
and manure. Weight value can be set from 1
to 99 lbs/kgs or OFF (00)

Weigh Method

[W MTHD]

GENERAL,

LOCK

Select weight method.

Lock-On

[LOCKON]

0.50, 0.75, 1.00,
1.25, 1.50, 1.75,
2.0,

5.0

, 10.0

Higher value will lock on quicker but sacrifice
accuracy. Use lowest setting that will
consistently lock-on to the same weight for a
restless animal.

Unlock

01-99(

50%

)

The percent of weight required to break the
lock and return to normal weighing.

Lock-N-Hold

[LKNHLD]

ON/

OFF

Holds “Lock-On” weight restarts when next
animal steps on.

Auto Off

[AUTOFF]

15,30,45,60,

OFF

Indicator shuts “OFF” after set period of
inactivity.

Display Count

[COUNT]

.01,.02,.05,.1,.2,.5,

1

,2,5,10,20,50,100

Select display count size (resolution) of
scale.

Auto-Range

[RANGE]

ON/

OFF

Scale increases display count size for
weights over 300 again at 600 lbs/kgs.

Display Unit

[LB-KG]

LB

/KG

When changing weight unit calibration
adjusted so scale displays accurately in new
display unit.