Menus and calibration – Digi-Star Stockweigh 300 User Manual
Page 17
Menus and Calibration
D3734-US Rev E
SW300 User’s Manual
13
MENUS AND CALIBRATION
1. Press and hold for 3
seconds.
2. Press O repeatedly until
desired setting shows.
3. Press to change setting
option.
4. Press to save setting and
advance to next setting.
5. Press O repeatedly until
indicator returns to weighing mode.
SETTING
[display]
Options [displayed]
BOLD = DEFAULT
DESCRIPTION
Zero Tracking
[ZTRACK]
1-99/
OFF
Adjusts to zero for build-up of snow, mud
and manure. Weight value can be set from 1
to 99 lbs/kgs or OFF (00)
Weigh Method
[W MTHD]
GENERAL,
LOCK
Select weight method.
Lock-On
[LOCKON]
0.50, 0.75, 1.00,
1.25, 1.50, 1.75,
2.0,
5.0
, 10.0
Higher value will lock on quicker but sacrifice
accuracy. Use lowest setting that will
consistently lock-on to the same weight for a
restless animal.
Unlock
01-99(
50%
)
The percent of weight required to break the
lock and return to normal weighing.
Lock-N-Hold
[LKNHLD]
ON/
OFF
Holds “Lock-On” weight restarts when next
animal steps on.
Auto Off
[AUTOFF]
15,30,45,60,
OFF
Indicator shuts “OFF” after set period of
inactivity.
Display Count
[COUNT]
.01,.02,.05,.1,.2,.5,
1
,2,5,10,20,50,100
Select display count size (resolution) of
scale.
Auto-Range
[RANGE]
ON/
OFF
Scale increases display count size for
weights over 300 again at 600 lbs/kgs.
Display Unit
[LB-KG]
LB
/KG
When changing weight unit calibration
adjusted so scale displays accurately in new
display unit.
1
2
3
4
5