Menu 4, Calibration, Bold – Digi-Star SW4600EID User Manual

Page 26: Setpnt, Over

Advertising
background image

SW4600EID

Setting/
Display

D.A.N Options

(

Bold

= Default)

Description

WM1
ADJUST 2

(

WMA 1-2

)

306

0,1,2,3,

4

,5,6,7,8,9

0=OFF Use values less than
WMA 1-1 for quick weight
response.

WM1
ADJUST 3

(

WMA 1-3

)

307

400

Enter weight to activate quick
weight response.

WM2
ADJUST 1

(

WMA 2-1

)

311

30

Increase number to smooth
weighing

WM2
ADJUST 2

(

WMA 2-2

)

312

10

0=OFF Use values less than
WMA2-1 for quick weight
response.

WM2
ADJUST 3

(

WMA 2-3

)

313

400

Enter weight activate quick
weight response.

MENU 4

Buzzer

(

BUZZER

)

404

1

-4, ON, OFF

Decrease # shortens alarm
horn

Relay

(

RELAY

)

406

SETPNT

/OFF

Set control for 12 VDC alarm
Press enter @ setpnt gives
option to enter value

Gross Set
Point Chng

(

SETCHG

)

424

50

Weight below SETPNT to
change 12VDC alarm

SETDEL

425

0

Time before 12 VDC alarm
output changes

SETOUT

426

OVER

/UNDER

12 VDC alarm = +12 VDC
when over or under setpnt

SETCTR

427

0,

1

,2,3,4,5,6,7,8,9

Use keypad to enter values.

CALIBRATION

Tcalb

801

ON

/OFF

Scale adjust for temperature
changes

Zero

802

Add Wt

Enter weight amount on scale

26