SW4600EID
WEIGH METHODS
Select weigh method #4 in menu 1 for animal weighing. EID features
require indicator set this mode. Using StockWeigh for stable loads, Lock-
On Weigh method ok. Other methods listed below.
Note: Most of StockWeigh features require weigh method #4.
General Weigh Method #1
All purpose weigh method for weighing stable loads.
Slow Weigh Method #2
Higher accuracy weighing for stable loads.
Fast Weigh Method #3
Determines new weight quickly. This method is for weighing stable loads.
Lock-on Weigh Method #4
Weigh active animals and display stable accurate weight. Set to “OFF” for
weighing stable weights. Lock-On sensitivity adjusted using “LOCKON”
menu.
Once actual weight displayed, scale “Locks-On” to weight. Weight display
stable, even if motion never stops. Small ‘L’ appears on left side of display
indicating weight “Locked-On.” Animal’s weight must be greater than 2.5%
of scales “capacity” weight before system can “Lock-On.”
To break lock, add or remove 50% of displayed weight. “Locked-On”
weight can be “rechecked”, press . this breaks “lock” and scale
recalculates weight.