Weigh methods, General weigh method #1, Slow weigh method #2 – Digi-Star SW4600EID User Manual

Page 34: Fast weigh method #3, Lock-on weigh method #4

Advertising
background image

SW4600EID

WEIGH METHODS

Select weigh method #4 in menu 1 for animal weighing. EID features
require indicator set this mode. Using StockWeigh for stable loads, Lock-
On Weigh method ok. Other methods listed below.
Note: Most of StockWeigh features require weigh method #4.

General Weigh Method #1

All purpose weigh method for weighing stable loads.

Slow Weigh Method #2

Higher accuracy weighing for stable loads.

Fast Weigh Method #3

Determines new weight quickly. This method is for weighing stable loads.

Lock-on Weigh Method #4

Weigh active animals and display stable accurate weight. Set to “OFF” for
weighing stable weights. Lock-On sensitivity adjusted using “LOCKON”
menu.
Once actual weight displayed, scale “Locks-On” to weight. Weight display
stable, even if motion never stops. Small ‘L’ appears on left side of display
indicating weight “Locked-On.” Animal’s weight must be greater than 2.5%
of scales “capacity” weight before system can “Lock-On.”

To break lock, add or remove 50% of displayed weight. “Locked-On”

weight can be “rechecked”, press . this breaks “lock” and scale

recalculates weight.

34

D3740