Troubleshooting, Operators manual – Digi-Star SW4600EID User Manual

Page 43

Advertising
background image

Operators Manual

TROUBLESHOOTING


























YES

NO

START

Check for 12VDC at the AC/DC convertor

power cord. If you do not have a multimeter,

use a car battery to power scale. If indicator

still does not come on, send in for repair.

Check for debris around

and under platform and

load cells. Check for

warped or damaged
mounts on platform.

NO

YES

YES

The other load cell is defective. Check

its cable for cuts or flattened areas or

send it back for repair. Check defective

load cell by connecting it to indicator

and verify it does not weigh.

YES

NO

Check for debris around

and under platform and

load cells. Check load

cell cables for cuts and

flattened areas.

YES

NO

Does the scale weigh you

close to your weight?

Disconnect the load cell cable from the

indicator. Press the indicator “TARE”

button. (indicator display should go to zero)

Stand on the load cell. Does it display a

reading about twice your weight?

YES

NO

Disconnect the first load cell and connect

the other load cell to the same connector

on the indicator. Does the indicator display

a reading about half your weight?

The other load cell is

defective, check its cables

for cuts or flattened areas

or send it back for repair.

Does indicator respond

when you step on scale?

NO

Disconnect one of the load cells and

stand over the connected load cell.

Does the indicator display a reading

about twice your weight?

Does the indicator come on?

YES

NO

YES

NO

YES

NO

This load cell is OK.

Disconnect first load cell

and connect other load

cell to same connector.

Now stand over second

load cell. Does it weigh

about twice your weight?

Disconnect first load

cell and connect other

load cell to same

connector. Now stand
over second load cell.

Does it weigh about.

twice your weight?

Perform a paper clip test. Take two

paper clips and carefully insert one into

pin 2 and the other into pin 3 of either

load cell connector jack on indicator.

Hold one paper clip in each hand (if they

touch it will not damage indicator) Does

reading on indicator jump around?

This load cell is

defective. Check its

cable for cuts or

flattened areas or send

it back for repair.

Check indicator using a

known good load cell.

The other load cell is

defective. Check its

cable for cuts or

flattened areas or send

it back for repair.

Both load cells are defective.

Indicator is probably OK. Check

the cables for damage and send

both load cells in for repair.

Indicator is defective. Send it in for

repair. Note: Load cells may also be

defective. Check load cells by

attaching to a working indicator

NO

Connect the load cell to other
connector on indicator. Stand

on load cell. Does it display

about twice your weight?

Check platform for

debris and mud

interference. Check

mounts for binding

and obstructions.

YES

Indicator is defective.

Verify this by substituting

a good working indicator

Do both load cells weigh you

about the same but not within

20% of twice your weight?

NO

Connect both load cells

(one at a time) to other

connector on indicator. Do

both load cells weigh you

about twice your weight?

YES

One of the load cells is bad. A good load

cell will weigh you at about twice your

weight with only one load cell connected.

NO

D3740

43

Advertising