WMV, WMVS USER INSTRUCTIONS ENGLISH 26999970 10-12

Page 11 of 28

flowserve.com

3.3.5 Seal housing
The seal housing has spigots between the pump
casing and bearing housing for optimum
concentricity.

3.3.6 Shaft seal
The mechanical seal(s) attached to the pump shaft
seals the pumped liquid from the environment.

3.3.7 Driver
The pump is driven by a close coupled electric motor.

The position of the terminal box can be changed by
rotating the complete motor. To do this, remove the
fasteners from the motor flange, rotate the motor and
refit the fasteners.

3.3.8 Accessories
Accessories may be fitted when specified by the
customer.

3.4 Performance and operating limits

This product has been selected to meet the
specifications of the purchase order. (See section 1.5.)

These pumps are generally fitted with TEFC motors
with an ambient temperature limit of 40 °C. Specific
pumps may be fitted with motors to suit client's
requirements with other ambient temperature limits -
see motor nameplate for details.

3.4.1 Pressure limits
The operating pressure has been selected to meet
your specified requirements. See paragraph 1.5,
Duty conditions,
for details.

Pump size

Max. working pressure

bar g (psi)

5WMV, 8WMV

24 (348)

16WMV

30 (435)

5WMVS, 8WMVS

29.5 (428)

16WMVS

41 (595)

Maximum suction pressure is dependent on

the number of pump stages. Suction pressure plus
closed valve head must not exceed the maximum
working pressure stated above.

3.4.2 Temperature limits

Pump

size

No of

stages

Maximum liquid temperature ºC (ºF)

at pump rotational speed

3 500

rpm

2 900

rpm

1 750

rpm

1 450

rpm

5 and 8

WMV(S)

30

N/A

35 (95)

35 (95)

35 (95)

24

N/A

100 (212) 100 (212) 100 (212)

20

35 (95)

100 (212) 100 (212) 100 (212)

18

35 (95)

100 (212) 100 (212) 100 (212)

16

100 (212) 100 (212) 100 (212) 100 (212)

14

100 (212) 100 (212) 100 (212) 100 (212)

12

100 (212) 100 (212) 100 (212) 100 (212)

10

100 (212) 100 (212) 100 (212) 100 (212)

8

100 (212) 100 (212) 100 (212) 100 (212)

6

100 (212) 100 (212) 100 (212) 100 (212)

5

100 (212) 100 (212) 100 (212) 100 (212)

4

100 (212) 100 (212) 100 (212) 100 (212)

16

WMV(S)

and

WMV(S)

24

N/A

35 (95)

35 (95)

35 (95)

20

N/A

35 (95)

35 (95)

35 (95)

18

N/A

35 (95)

35 (95)

35 (95)

16

N/A

100 (212) 100 (212) 100 (212)

14

35 (95)

100 (212) 100 (212) 100 (212)

12

35 (95)

100 (212) 100 (212) 100 (212)

10

100 (212) 100 (212) 100 (212) 100 (212)

8

100 (212) 100 (212) 100 (212) 100 (212)

6

100 (212) 100 (212) 100 (212) 100 (212)

5

100 (212) 100 (212) 100 (212) 100 (212)

4

100 (212) 100 (212) 100 (212) 100 (212)

4 INSTALLATION

Equipment operated in hazardous locations

must comply with the relevant explosion protection
regulations. See section 1.6.4, Products used in
potentially explosive atmospheres.

4.1 Location

The pump should be located to allow room for access,
ventilation, maintenance and inspection with ample
headroom for lifting and should be as close as
practicable to the supply of liquid to be pumped. Refer
to the general arrangement drawing for the pump set.

4.2 Part assemblies

These pumps are not normally supplied in part
assemblies but special accessories such as loose
orifice plates are supplied loose. Ensure these are
incorporated in the final installation.

4.3 Foundation

There are many methods of installing

pump units to their foundations. The correct method
depends on the size of the pump unit, its location and
noise and vibration limitations. Non-compliance with
the provision of correct foundation and installation
may lead to failure of the pump and, as such, would
be outside the terms of the warranty.