Flowserve WMV IDP User Manual

Page 21

Advertising
background image

WMV, WMVS USER INSTRUCTIONS ENGLISH 26999970 10-12

Page 21 of 28

flowserve.com

j)

Push the location pin into the drilled hole in the
pump shaft, place the two coupling halves around
the shaft locating on the pin and loosely bolt
together with the four socket head screws.

k) Carefully lower the motor into place onto the

spigot on the motor stool.

l)

Position the terminal box to the outline
arrangement drawing, or as required, and
securely tighten the four motor retaining bolts.


6.9.2 Positioning the pump shaft
a) Position pump shaft 1.5 mm (0.06 in.) above bottom

position (2 mm [0.08 in.] on size 16WMV) using
shims or taper gauges between the bottom face of
the coupling and the top face of the motor stool.

b) Tighten the socket head screws in coupling to

torque listed. During tightening ensure that the
two faces of the coupling halves remain parallel
with an equal gap each side.

c) Spring the coupling guards into the grooves in the

motor stool.

Advertising