12

9.5 Push the end into the adhesive

and check the gasket extension

with the height gauge. Hold it

in place for 10 seconds.

See Figure 25.

9.6 Glue the other seat gasket end

into the groove using the same

steps.

8.7 Push the draped middle of the

gasket into the groove. Make

Figure 25

sure this gasket is fully seated in the groove. Do not apply adhesive.

9.8 Repeat this procedure for the other gland half.

the groove of the joint surface

where the threaded cap screw

holes are located.

10.3 Wipe the gland split joint gasket

groove clean with alcohol.

Caution: Consult material safety data

sheets for proper handling of

alcohol.

Note: Care must be taken to avoid

getting the adhesive too close

to the seat gasket or the gland

gasket. These should not be

glued together.

10.4 Put three dots of adhesive in the

groove as shown in Figure 26.

10.5 Place the split joint gasket in the

groove. The split joint gasket

Figure 27

Figure 26

Adhesive dot here

should be flush with the gland gasket groove surface, top of the

seat gasket, and top of the split joint gasket groove. Hold it in place

for 10 seconds. See Figure 27.

10.6 Repeat this procedure for the other gland half.

10 Gland Split Joint Gasket Installation

10.1 Loosen the gland cap screws and completely separate the gland

halves.

10.2 Each gland half has split joint gasket grooves machined into

each joint surface. The split joint gasket should be installed in

Flush