14 stationary face installation, 13 rotating face installation – Flowserve PSS III Durametallic User Manual

Page 14

Advertising
background image

14

Figure 33

13.5 Repeat this procedure for the other seal drive half.
13.6 Lubricate the exposed surfaces of each sleeve gasket including

the ends and the split joint gaskets with silicone grease.

13.7 Wipe the rotating faces clean with alcohol.
Caution: Consult material safety data sheets for proper handling of

alcohol.

14 Stationary Face Installation

14.1 Lubricate the exposed surfaces of the seat gasket including the

ends, the stationary face shoulder, and the stationary face back

surface that contacts the spring holder with silicon grease.

13.1 Set the seal drive face up on the

bench. Lubricate both sides of

the vibration damper with silicone

grease. Place the vibration

damper on the seal drive rotating

face support surface using the

drive pin as a locator.

See Figure 32.

13.2 Lubricate the exposed surfaces

of the rotating face gasket

including the ends and the

rotating face shoulder with

silicone grease.

13.3 Position the rotating face back

surface downward over the

vibration damper aligning the

drive pin with the pin slot.

13.4 Push the rotating face radially

into the seal drive and then down

as the drive pin slips into the drive

slot. The rotating face should sit

flat on the vibration damper.

See Figure 33.

13 Rotating Face Installation

Figure 32

Advertising