Flowserve PSS III Durametallic User Manual

Page 3

Advertising
background image

3

These instructions are to be used in conjunction with the PSS III Repair

Kit. The Repair Kit contains replacement seal faces, secondary seals,

Loctite 430 adhesive, and Dow Corning 111 Silicone grease. Other

small parts are shown in Figure 1. The repair should be done in a clean,

well lit area. The tools you will need to do the repair include:

• Suitable solvent and rinse

• Alcohol

• Paper towels and/or swabs

• Single edged razor blade or Exacto style knife

• Common screw driver

• Hex key wrenches

• Paper clip

• Anti-seize thread compound

These instructions require the gluing of elastomers into position with

Loctite 430. As with any cyanoacrylate, extreme care must be used when

handling Loctite 430. See the enclosed Material Safety Data Sheet for

details.
For special problems encountered during the repair procedure, contact

your nearest Flowserve Sales and Service Representative or Authorized

Distributor.

® 1

® 2

TM

1 Registered Trademark of Loctite Corporation

2 Registered Trademark of Dow Corning Corporation

Figure 1

A Rotating Face
B Stationary Face
C Adhesive
D Lubricant
E Setting Device
F Split Jount

Gasket

G Height Guage
H Setting Device
I Vibration Damer
J Split Joint Gasket
K Seat and

Rotating Face

Gaskets

A

B

C

D

E

F

G

H

I

J

K

Advertising