14.4 Push the stationary face radially into the gland and then down as
the lock pin slips into the lock pin slot. The stationary face should
sit flat on the spring holder.
14.5 Repeat this procedure for the other gland half.
14.6 Lubricate the exposed split joint gasket surfaces with silicon grease.
14.7 Wipe the stationary faces clean with alcohol.
Caution: Consult material safety data sheets for proper handling of
alcohol.
For proper seal installation, please refer to Flowserve publication
FIS175eng, PSS III Installation Instructions.
Figure 34
14.2 With the gland half sitting on the bench, position the stationary face
over the spring holder as shown in Figure 34.
Figure 35
14.3 Align the lock pin a with the lock pin slot. See Figure 35.