DURCO BX2001 USER INSTRUCTIONS ENGLISH 9-13

27

SECTION X
LOCKING LEVER HANDLE AND INDICATOR PLATE INSTALLATION

(See FIGURE 7 below.)

1. Close the valve. The flats on top of the stem should be

parallel with the valve flange face. (Refer to FIGURE 7.)

Note: At this time, adjustments should be made to

ensure that the valve body’s machined flanged surface

(5) is parallel with the disc. To accomplish this, place the

valve body’s machined flanged surface (5) on a level

plate. Position a bubble level on the upper side of the

shaft flat and adjust the shaft until completely level.

2. Place bracket (6) on the valve body as shown in FIGURE

7. Attach using the bracket fasteners (7), lock washers

and hex fasteners. Secure hex fasteners finger-tight.

3. Mount the indicator plate (1) to the bracket (6) as shown

in FIGURE 7 with the shakeproof washers placed between

the indicator plate (1) and the bracket (6). The indicator

plate fasteners (4) should be finger-tight at this time.

4. Place the locking lever handle (2) on the valve stem as

shown in FIGURE 7 and tighten the pinch fastener (3)

provided.

5. Position the indicator plate (1) so that the locking lever

fits in the “closed” position of the indicator plate (1).

Tighten the indicator plate fasteners (4) and the bracket

fasteners (7). (Be sure that the lever cannot be moved

with a

5

/

16

padlock installed in locking hole.)

6. Cycle the valve from closed to open, to closed again,

using the locking lever handle. Recheck to make sure the

disc is centered on the seat by measuring the distance

from the machined surface on the disc to the machined

flanged surface (6) on the body. This should be done at

two points, one above or below the disc over travel stop

and the other 180 degrees from the first. Both measure-

ments should be equal.

SECTION XI
CHANGING LOCKING LEVER HANDLE QUADRANTS

Do not attempt to change locking lever handle quadrants while

the valve is in service.
1. Close the valve. The flats on top of the stem should be

parallel with the valve flange face. Depressurize system

if valve is installed as valve could open when the locking

lever handle is removed.

2. Remove the locking lever handle (2) and indicator

plate (1).

3. Mount the indicator plate (1) 180 degrees from the

position shown in FIGURE 7. Do not tighten the indicator

plate fasteners (4) at this time.

4. Follow Steps 4 and 5 in the Locking Lever Handle and

Indicator Plate Installation Instructions above.

FIGURE 7

(DVENIM0390-02)-BX2001_update.indd 27

10/10/13 2:08 PM