TYPE (b) TORQUE ONLY

DISASSEMBLY PROCEDURE

Limitorque Illustration No.22
AUMA Illustration No.23

1. Position the valve gate just off the

seat.

2. Disconnect the electrical wiring to the

actuator.

3. Position a chain hoist of adequate

capacity to the actuator. The pull
point must be directly in line with the
valve stem.

4. Remove all nuts or cap screws from

under the flange.

5. Using a hoist, raise the actuator

above the yoke bushing and position
away. If the actuator is keyed to the
yoke bushing, remove the key so it
will not be lost.

If there is further work to do on the
valve, refer to the proper valve type and
proceed with disassembly.

CAUTION:

UPON REASSEMBLY OF A VALVE EQUIPPED

WITH AN ELECTRO-MECHANICAL

ACTUATOR, THE OPEN AND CLOSED LIMIT

SWITCHES MUST BE RESET. PLEASE REFER

TO THE MAINTENANCE MANUAL PRO-

VIDED BY THE ACTUATOR MANUFACTURER

FOR APPROPRIATE INSTRUCTIONS.

WARNING

SHOULD IT BECOME NECESSARY

TO CHANGE THE TORQUE SWITCH

SETTING FOR ANY REASON, YOUR

LOCAL EDWARD VALVES REPRESENTATIVE

SHOULD BE CONTACTED IN ORDER

THAT A CORRECT NEW SET CAN BE

OBTAINED FROM THE FACTORY.

The torque switch of the motor actuated
valve is set during factory assembly to
close the valve against the specified differ-
ential pressure and requires the same spe-
cial attention for resetting.