1 to replace the stem nut only – Flowserve SMB Series Electric Actuators User Manual

Page 57

Advertising
background image

57

SMB Series/SB Series Installation and Maintenance FCD LMENIM1401-04-AQ – 01/15

flowserve.com

Table 7.2 – SMB-00 Parts List (continued)

Piece

Quantity

Description

141

4

Flat Head Machine Screw

143

3

Pipe Plug (Only 1 shown)

144

4

Pipe Plug (Only 3 shown)

148

1

Drive Sleeve Bevel Gear

154

2

Socket Head Cap Screw

156

1

Key

157

6

Socket Head Cap Screw

158

6

Lockwasher

159

4

Lockwasher

160

4

Round Head Machine Screw

162

4

Flat Head Socket Cap Screw

164

1

Key

165

2

Socket Head Set Screw

166

1

Socket Head Cap Screw

167

1

Lockwasher

168

2

Key

169

1

Key

170

1

Socket Head Set Screw

173

1

Hex Head Cap Screw

174

4

Stud

175

4

Hex Nut

176

4

Lockwasher

177

1

Socket Head Set Screw

178

1

Key

7.3 SMB-0, 1, 2, 3 and 4

c

WARNING: See Section 4.1 and 4.2 on Safety Precautions and Safety Practices before
proceeding with disassembly.

7.3.1 To Replace the Stem Nut Only

c

WARNING: Do not remove the Locking Nut (piece #30) with the actuator under load or with valve
under pressure.

a

CAUTION: If valve must be left in service while the stem nut is replaced, the valve stem must be
locked in such a way as to prevent any movement of the valve stem.

1. Remove Locking Nut (piece #30). The locking nut is staked in two places; locate the stakes and

spot with a drill.

2. Clean all metal particles.

3. Lift Stem Nut (piece #20) out of the top of the actuator.

If the actuator is mounted on a valve having a threaded stem, and stem nut removal is required,

proceed as follows:
1. Remove Locking Nut (piece #30).