Mounting to Standard Valtek Rotary Valves

(See Figure 4)

Figure 4: Standard Rotary Mounting

Positioner Bolts ¼-20 (4)*

* Located in appropriate

hole pattern as indicated on

bracket. (25, 50, 100/200)

Take-off Arm, Rotary
Lock Washer (2)
10-32 Bolt
10-32 Nut

Self-tapping Screws (2)

Spline Lever Adapter

10-32 Nut
Lock Washer

Follower Arm

Logix 3400IQ

Digital Positioner

Bracket Bolts

-18 (2, not shown)

5

/

16

The standard rotary mounting applies to Valtek valve/actuator assemblies that do not have mounted
volume tanks or handwheels. The standard mounting uses a linkage directly coupled to the valve
shaft. This linkage has been designed to allow for minimal misalignment between the positioner and
the actuator. The tools required for the following procedure are:

5

32

" Allen wrench

• 1/2" open-end wrench

7

16

" open-end wrench

3

8

" socket with extension

3

16

" nutdriver

1. Fasten the spline lever adapter to the splined lever using two 6 x 1/2" self-tapping screws.

2. Slide the take-off arm assembly onto the spline lever adapter shaft. Insert the screw with star

washer through the take-off arm and add the second star washer and nut. Tighten nut with
socket so arm is lightly snug on the shaft but still able to rotate. This will be tightened after
linkage is correctly oriented.

3. Attach follower arm to positioner feedback shaft using the star washer and 10-32 nut.