TB3 - Audio Output and Data Connections

The TB3 connector (labeled

AUDIO)

provides connections for audio inputs and outputs, and for local

RS485 data connections. Data connections are used when the AMI alarms are being controlled remotely
from a CPU or when the Model 12584-001 I/O Control Module is used to expand the inputs and outputs
to 40 each. A 600-ohm balanced audio output is provided to drive a power amplifier. Refer to the TB3
terminal block assignment chart and Figure 4 below.

N

OTE

: If only 600-ohm audio will be used, ensure that jumper P7 is installed in position 1-2 to properly

terminate the 33-ohm output. Refer to Table 8, 69517-202 PCBA Jumper Functions, on page 14.

Table 4. Terminal Block 3 Assignments

Terminal Labeled

Description Function

TB3-1

LINE

-

Page (L1)

TB3-2

LINE

+

Page (L2)

Audio output (line level) to public address amplifier.
Refer to Figure 4.

TB3-3

L1

Audio 2 (L1)

TB3-4

L2

Audio 2 (L2)

No customer connections – used for internal
connections to Telephone Interface PCBA

TB3-5

L1

Audio 1 (L1)

TB3-6

L2

Audio 1 (L2)

No customer connections – used for internal
connection to Telephone Interface PCBA.

TB3-7

POWER

GND

Power ground

Power supply common

TB3-8

DATA

GND

Data ground

N/C

TB3-9

DATA-

Data (-)

To Model 12584-001 I/O Control Module (TB2-2)

TB3-10

DATA+

Data (+)

To Model 12584-001 I/O Control Module (TB2-1)

Figure 4. Typical amplifier input wiring

Advertising