Installation – GAI-Tronics 10959-101 Wall-Mount Audio Messenger Interface (AMI) User Manual

Page 9

Advertising
background image

Pub. 42004-398E

M

ODEL

10959-10

X

W

ALL

-M

OUNT

A

UDIO

M

ESSENGER

I

NTERFACE

P

AGE

7 of 31

f:\standard ioms - current release\42004 instr. manuals\42004-398e.doc
10/09

Controls......................................................................................................................S1: data address switch

R120: audio level from telephone line

R122: audio level to telephone line

Network signaling.......................................................................(via Registered SPRLM-3 Module) DTMF

Supervision ..................................... Telephone line battery wink or polarity reversal or audio silence timer

Minimum required loop current........................................................................................................... 25 mA

Registered Telephone Line Module (SPRLM-3 Module)

Trade name...............................SPRLM-3 Registered Line Module Equipment Type: Analog Line Module

Controls................................................................................................Access, Off-hook detect level jumper

Connections......................................................................................Telephone Line: E1-E2 screw terminals

Power and control: 9-pin female inline, for mating with

0.1 inch pitch

× 0.025 inch square pin header

Page/Party

®

Interface

Page line..................................................................................................... 33-ohm nominal load impedance

Party line ........................................................................................... 33-ohm nominal ac source impedance

Page line output level...................................................................................... Adjustable; 1.5 V

RMS

nominal

Inputs/outputs......................................................... Page line, 5 party lines, audio level 1.5 V

RMS

maximum

Audio to/from AGI Main and Page/Party

®

PCBA 1.0 V

RMS

maximum

Controls..........................................................................................................POT1: audio level to party line

POT2: audio level to page line

Installation

Power Disconnect. The power cord is the main power disconnect for all units.

Disjontion de l’alimentation. Le cordon d’alimentation est la disjonction d’alimentation

principale tous les appareils.

Para Desconectar la Alimentación: El cable de alimentación es el medio principal de

desconexión del equipo.

Netzanschluß. Wenn man das Netzkabel aus der Steckdose zieht, dann ist die

Spannungszuführung zum Gerät vollkommen unterbrochen.

CAUTION

To reduce the risk of fire, use only No. 26 AWG or larger telecommunication

line cord.

ATTENTION

Pour réduire le risque d’incendie, utiliser uniquement des conducteurs de

télécommunications 26 AWG ou de section supérieure.

PRECAUCIÓN

Para aminorar la posibilidad de incendios, utilice solamente cable de

telecomunicaciones de calibre 26 (sistema AWG americano) o mayor.