Guralp Systems CMG-DCM build <10,000 User Manual

Page 116

Advertising
background image

Acquisition Modules and Platinum Firmware

Digitiser Configuration

­­ids  sys   ser

― Specify new system ID and serial number to set

following a hard factory reset. This option will attempt to preserve the
previous values if new values are not specified)

­­samp   #   #   #   #

― Change the sample speeds for each of the four

decimation taps. This option requires four numeric values as supplied for the
SAMPLES/SEC command described in the DM24 manual.

­­cont # # # #

― Change which streams are produced as continuous

output from each of the decimation taps. This option requires four numeric
values as supplied for the CONTINUOUS command described in the DM24

manual.

­­trig # # # #

― Change which streams are produced as triggered output

from each of the decimation taps. This option requires four numeric values as

supplied for the TRIGGERED command described in the DM24 manual.

­­gps­baud #

― Set the line speed for the GPS port. This option requires a

single numeric value: the new line speed to use.

­­in­baud #

― Set the line speed for the DATA IN port. This option

requires a single numeric value: the new line speed to use.

­­upgrade

― Upgrade firmware files only (this is the default).

­­downgrade

― Allow firmware files to be downgraded as well as

upgraded.

­­force

― Firmware files are to be loaded even if they appear identical, or

the installed version number cannot be decoded.

­­boot file

― Specify a source file for DM24mk3 bootstrap. This option

requires a single value, file, which is the path to the firmware image file to

be loaded.

­­firm file

― Specify a source file for DM24mk3 or CD24 firmware. This

option requires a single value, file, which is the path to the firmware image

file to be loaded.

­­dsp file

― Specify a source file for DM24mk3 DSP code. This option

requires a single value, file, which is the path to the firmware image file to

be loaded.

­­auto­baud S

― can for digitiser baud rate and adjust configuration. If

possible.

­­verbose

― Show most of the digitiser dialog.

­­debug Output some additional debug information from the underlying

expect script.

MAN-EAM-0003

116

Issue E - February 2014

Advertising