Herrtronic, Md series – Herrmidifier Herrtronic MD Engineering Guide User Manual

Page 4

Advertising
background image

Herrtronic

®

MD Series

E n g i n e e r i n g G u i d e

4

www.herrmidifier-hvac.com

Fill System:

Integral 1” air gap

prevents reverse

siphoning to potable

water supply

Adjustable

metering valve

accomodates water

pressures up to

100 psi

Strainer

Outlets - 1 ½” OD

(1) Outlet up to 50 lbs/hr

(2) Outlets thru 100 lbs/hr

(3) Outlets thru 250 lbs/hr

“Cylinder Full” Electrode

shuts fill solenoid off to

prevent overflow

Replaceable

Polypropylene Cyclinder

(1) Cyl. thru 100 lbs/hr

(2) 110-250 lbs/hr

Drain System - Sealed core drain valve. Drain frequency

and duration automatically adjust to water quality.

Isolated Control and

Electrical Compartment

Access Panel w/ lock

Door Interlock Switch

Prevents unit operation

w/ open door

Conductivity

Micromhos

(approx.)

70

100

135

170

255

510

765

1020

Average Life

Expectancy - Hrs

(approx.)

2000

2000

1900

1800

1300

800

650

500