9 mtbf, Specifications – IHSE USA 480 Series Draco tera enterprise User Manual

Page 193

Advertising
background image

Specifications

2013-08-14

193

7.9

MTBF

The following table contains the mean time between failure (MTBF) in
power-on hours (POH). The estimate is based on the FIT rates of the
parts included. FIT rates are based on normalized environmental
conditions of T = 60°C and activation energy (E

a

) of 0.7 eV. Calculations

are based on 90% confidence limit.

We estimate that inside the housing, temperature will be 15°C higher than
the ambient temperature. Therefore, the MTBF calculation refers to an
ambient temperature of 45°C. The humidity is limited to 60%.

Draco tera 288 chassis

260,000 POH

Draco tera 160 chassis

310,000 POH

Draco tera 80 chassis

320,000 POH

Draco tera 48 chassis

350,000 POH

CPU board

480,000 POH

I/O board SFP

500,000 POH

I/O board Cat X

410,000 POH

Draco tera 288/160 PSU 200,000 POH
Draco tera 80/48 PSU

130,000 POH


Pos: 157 /806-IHSE/Wartung/480-xx_Wartung @ 8\mod_1351506868807_6.doc @ 69520 @ 122222 @ 4