5. Clean suction strainers of build-up.

þ

NOTE:

V-cup seal on the drain overflow tube may
become gummed not allowing a proper seal
of the overflow tube. This will cause the drain to
leak water. Remove any build-up on the V-cup
seal. When the seal becomes worn, replace.

The following cleaning procedures should be done
daily, at the end of the shift.

Daily
1. Remove all internal removable parts including

spray manifolds, scrap screens, drain overflow
tubes, suction strainers and curtains.

2. Remove the end caps from the spray manifolds

and clean with the brush provided. Flush the
manifolds.

3. Flush scrap screens.

4.

Clean drain overflow tube.

PART 3 OPERATION & CLEANING INSTRUCTIONS

CLEANING PROCEDURES

7. Clean curtains. When curtains are beyond

cleaning or torn they should be replaced.

8. Final rinse nozzles should be cleaned of matter

clogging the jet spray.

9. Clean the photo-eye lenses with a damp, soft

cloth.

10. Doors should be left open to allow drying of

interior surfaces.

6. Clean tank level floats (2 per tank) with Scotch-

Brite or equivalent.

þ

NOTE:

Improper cleaning of suction strainer will cause
the pumps to cavitate. This will cause poor
washing results.

WARNING:

Level floats must be cleaned daily. Build-up of
grease and scum will cause faulty operation of
tank fill and heating system.

!