Level System
1. The level control system consists of a level

board (P/N DE7-35) for both the wash and rinse
tank and a level float (P/N DE5-60) per tank.

2. The level float will not allow the tank heat to

energize without water in the tank.

Final Rinse Actuator
1. The final rinse is actuated by the photo-eye

emitter and receiver located at the entrance to
the machine. See dwg. 1100-265.

2. When the beam is broken by a plate, etc., the

final rinse time is energized turning on the final
rinse solenoid and allowing the water to flow.
After one minute the timer will de-energize turn-
ing the solenoid off. The energy saver timer (P/N
DE7-28) is reset to 0 at the same time the final
rinse timer is energized. The energy saver timer
is adjustable between 0-300 SEC.

Conveyor Belt Adjustment
1. The conveyor belt tension is adjustable by locat-

ing two adjustment bolts on the load side of the
machine. The bolts can be moved in and out of
the conveyor follower shaft therefore adjusting
the belt tension.

Conveyor Overload Shut-off Mechanism

Adjustment (P/N 1100-289)
1. A clutchless overload is used to shut the

machine completely down should a jam occur
in the conveyor system. The jam may be caused
by ware being caught, bent tracks or misalign-
ment of the conveyor belt.

PART 4 MAINTENANCE & REPAIR PROCEDURES

CAUTION:

Should the tank heat energize without water in the tank,

troubleshoot the system to find the problem.

Check the floats.

WARNING:

Dirty level floats will cause the tank heat to
energize with no water in the tanks.
LEVEL FLOATS MUST BE CLEANED DAILY.

!