Installing filtration, Fill tank & then connect power, Final water connection – InSinkErator HC3300 User Manual

Page 5

Advertising
background image

Mark hole locations for filter head

and bracket in a spot that allows for

filter replacement.

Drill 3mm starter holes and attach

bracket to wall with wood screws,

turning until snug.

Remove red filter cap, insert filter

cartridge into filter head and twist

clockwise until “LOCK” arrow on the

filter aligns with arrow on bracket.

Personal Injury: Do not locate filter above an outlet or other

electrical device. Install head and bracket so that connections

require no stretching, kinking or pinching of tubing.

5

A

Determine length of tubing required,

then cut to length making sure the cut

is perpendicular and burr-free.

Insert a

white 9.5mm tube into inlet

side of filter head

until it stops. Press

in again to ensure a secure fit.

Insert the other

white tube into outlet

side of filter head

until it stops. Press

in again to ensure a secure fit.

Property Damage: Tube runs need to form to

the cabinet’s contours to allow storage space with

no sharp bends. Tubes need clean, perpendicular,

burr-free cuts to ensure a true fit.

From water

supply line

To tap

HC1100

From filter or

water supply line

HC1100 only: Remove plug from

“Y” quick connector by holding grey

release ring and gently pulling plug out.

Insert the copper tube(s) from the

tap into the 9.5mm to 6.35mm

quick-connector.

Press in again to

ensure a secure fit.

Connect the

white tube from the

right outlet on the filter head into the

quick-connector until it stops.

Press

in again to ensure a secure fit.

Property Damage: Do not extend the

copper lines farther than the 40cm provided.

To redirect filter replacement water

discharge, place 150mm clear tube

over vent hole on the left side of

filter head.

It is normal for approximately 60 ml of

water to discharge when filter is removed.

D

Discharge tube

From water

supply line

To tap

INSTALLING FILTRATION

5

Plug

Plug

B

C

HC3300, H3300,

GN1100

From filter or

water supply line

Scalding Hazard: The tap dispenses water up to

98ºC, which can instantly cause scalds or burns.

Use care when operating this appliance.

Scalding Hazard: The tap dispenses water up to

98ºC, which can instantly cause scalds or burns.

Use care when operating this appliance.

Turn on the cold water supply.

Depress the tap’s HOT handle and hold

it until water flows from the spout. Run

the water for at least 3 minutes to flush

lines (both the hot and cold handles on

HC1100 independently).

Check all connections to ensure they are

tight and that there are no leaks.

Plug in tank and ensure that green light

on front of tank is illuminated.

Note: See box below for special

instructions on operation of HC3300

and H3300 taps.

Featuring two-step hot side activation with

automatic shut off and cool side two-step

activation, which keeps the tap open when

dispensing cool water.

HC3300: To dispense instant hot water,

first

press down on the tap handle and

then push the handle backward in the

direction of the red indicator on the top

of the handle. To dispense cool water,

first

press down on the tap handle

and then pull the handle forward in the

direction of the blue indicator on the

handle.

Featuring two-step hot side activation with

automatic shut off.

H3300: To dispense instant hot water,

first

press down on the tap handle and

then push the handle backward in the

direction of the red indicator on the top

of the handle.

Water will be cold at first. Allow 12-15 minutes for water to reach target temperature.

Gurgling or hissing is normal during the initial heating cycle.

FILL TANK & THEN CONNECT POWER

7

A

Operating Instructions for HC3300 and H3300 taps

Dispensing Hot Water

(HC3300, H3300)

Dispensing Cool Water

(HC3300)

Property Damage: Join remaining

tube to cold water supply only.

AUS/NZ: See instructions provided with valve kit
At the other end of the white tube from the filter,

press on the:

(UK/IRL) 9.5mm to 15mm quick-connector

and connect to a 15mm water supply.

(AUS/NZ) 3/8" to 1/4" bspt John Guest

fitting and connect to a female 1/4" bpst

fitting water supply.

Press in again to ensure a secure fit.

FINAL WATER CONNECTION

6

UK/IRL

AUS/NZ

Back flow

protection valve

Wall mount

clip

A

Advertising