BASIC TROUBLESHOOTING

Power Supply Overheating, AC-DC Module / DC-DC Module:

• Air fl ow in the power supply may be restricted due to cooling fan not working properly, fan blocked, or clogged

ventilation slots around the power supply case.

• Turn off computer equipment and then the power supply.
• Check that the fan is not blocked. Check the ventilation slots around the power supply case for dust build-up and

clean.

• Turn on the power supply and restart the computer.
• If this problem continues, contact InterMetro Customer Service.

Battery Pack overheating:

• Turn off computer equipment and then the power supply.
• Let cool for 2 hours.
• Turn on the power supply and restart the computer equipment.
• If this problem continues, contact InterMetro Customer Service.

Battery Pack Overheating, Critical:

• System will shut down in 2 minutes.
• Immediately turn off computer equipment and then the power supply.
• Let cool for 2 hours.
• Turn on the power supply and restart the computer equipment.
• If this problem continues, contact InterMetro Customer Service.

No Battery Warning:

• No battery packs are detected in the power supply. Battery packs most likely are not connected before the power

supply was placed into service.

NOTE

: The battery cells are not connected during shipment due to USDOT AND IATA regulations.

• Turn off computer equipment and then the power supply.
• Make sure battery packs are connected by performing procedure in Section “Connecting the Power Supply

Batteries” above.

• Turn on the power supply and restart the computer equipment.
• If this problem continues, contact InterMetro Customer Service.

Power Supply / Battery Pack Low Temperature:

• System temperature below 0 °C (32 °F) has been detected. Ambient temperature is below operating range,

temperature sensor has failed or has become disconnected.

• If power supply or its workstation are in an area where the temperature is below 0 °C (32 °F - freezing), move to an

area of ambient temperature above 0 °C (32 °F - freezing), otherwise,

• Turn off computer equipment and then the power supply.
• Turn on the power supply and restart the computer equipment.
• If this problem continues, contact InterMetro Customer Service.

Output Fuse Blown:

• The DC output fuse is blown.
• Immediately turn off the power supply.
• Check your workstation cart for a possible short.
• Replace the fuse as specifi ed in “Fuse replacement” below.
• Turn on the power supply and restart the computer equipment.
• If this problem continues, contact InterMetro Customer Service.

Fuse replacement

CAUTION

: For continued protection against risk of fi re, replace only with the same type and rating of fuse.

• AC input: No fuse
• DC output: F 12 A 32 V (Fast acting 12 A 32 V fuse ¼ x 1¼ in, glass)