Operation, Management – Microsens Fast Ethernet 2 Port Multifunction Bridge User Manual

Page 7

Advertising
background image

Multifunctional Bridge 10/100Base-TX/100Base-FX

Page 7/8

MICROSENS GmbH & Co. KG - Kueferstr. 16 - D-59067 Hamm / Germany - Tel. +49 (0)2381/9452-0 - Fax -100 - www.microsens.com

Operation


The module is designed for the mounting into a MICROSENS modular chassis. It can be
combined with all other converter modules of the same series.

The power supply is done by a central power supply unit via the backplane of the
chassis. Together with the power supply it is possible to insert to insert up to 12
modules into the 3 U chassis. Optional it is possible to insert a second redundant power
supply. In this case it is possible to use up to 10 converter modules.

Beside the 3 U chassis there is an additional 1 U chassis (horizontal slots) available. This
chassis has an integrated power supply (MS416006), which can be also redundant
(MS416007).

Furthermore there are in addition to the 19” racks, desktop chassis for one (MS417001)
or two (MS417041) modules available. With the wall bracket (MS417001-WH) it is
possible to mount the desktop chassis on the wall.


Management


The module can be configured and monitored by the central management agent. There
are two different modes possible:

DIP-13 off

Monitoring of the actual configuration and operation states,
configuration through the NMS is not possible.

DIP-13 on

Monitoring with Network management (SNMP- and web based),

configuration by web management, terminal or telnet connection.


The SNMP and web based management features of the system are provided by the
management master module (MS416020). When choosing the management features it
is necessary that the chassis (e.g. MS416001M) and the power supply (MS416004M) are
also supporting the management.

Visualising - and
configuration-
example with an SNMP
management platform:

3 U chassis MS416001

Power supplies MS416004M (redundant)

Twin bridge manageable (e.g. MS416360M)

Advertising