symmetrically controlled. Excessive rise time may result in the pulse never

reaching the set value. With the width set at a high percentage, excessive

rise time will prevent the output from dropping back to the “background” value.
All functions may be remotely controlled by application of a -0- to 10 V. Direct

Current level to the appropriate pins of the remote connector and placing the

control switch in the “Remote” position. (See Page 20)
Control Summary - 0% to 100% dial settings (Calibration is in percent of

maximum value given).

Background Level 0 to 50 volts, 0-300 amperes

Background Slope 0 volts per ampere (CV) to 0 amperes per volt (CC)

Pulse Level 0 to 50 volts, 0-300 amperes
Pulse Slope 0 volts per ampere (CV) to 0 amperes per volt (CC)
Inductance 0 to 3 millihenries equivalent
Pulse Rate 20 to 2000 pulses per second
Pulse Height 0 to 50 volts, 0 to 300 amperes
Pulse Width 0 to l/pulse frequency
Pulse Time 200 msec to no rise
(see graph)

The following Figures show control characteristics:
Figure 9

Background Slopw & Pulse Slope

Figure 10

Background Level & Pulse Level

Figure 11

Output Wave Form - 50% Pulse Width vs Frequency

Figure 12

Pulse Rise Time vs Dial Settings

The MK2000A and the C1-A Remote Control

The 25 pin D connector on the front panel of the MK2000A enables the power

supply to be remotely controlled through 0 to 10V analog commands. To use

an existing C1-A Pendant, P/N 001-0002, with the MK2000A, the following

25 pin "D" connector cable assembly must be used: P/N 843-0306. When

the C1-A pendant is used in conjunction with the MK2000A, several operating

modes are avialable.

Remote Heat Only

Set desired parameter on power supply, insuring that the mode selector

switch is in the “heat” position. Placing switch 10 in the remote position now

removes the heat control from the front panel to the C1-A pendant.

Full Pendant Operation

Placing switches 1 - 10 in remote provides full C1-A type operation.

NOTE:

Because the C1-A is calibrated to the MK2000’s 40 volt range rather than the

MK2000A’s 50 volt range, it may be necessary to recalibrate the C1-A Pendant.

When recalibration is necessary, consult the factory for procedure instructions.