Step 3.
Cut zap strap securing wires together in bundle.
Figure 6. Section 6
Step 4.
Cut off large bell connector connecting white fibre wire from power
cable, black wire from blower and one black wire from capacitor. Cut as little
as possible, there is not much space.
Figure 7. Section 6
Step 5.
Cut off small bell connector connecting brown wire from blower and
the other black wire from capacitor.
Figure 8. Section 6
Step 6.
Unscrew old capacitor and discard. Secure new capacitor in its
place.
Figure 9. Section 6