Installation, Wiring, Removing and installing the in- ner doors – Montigo M38DV PRC User Manual

Page 9: Gas control and pilot wiring, Fan wiring, Door removal, Door installation, Page, Panorama direct vented fireplace

Advertising
background image

Page 

XG0204 04/05

Panorama Direct Vented Fireplace

Installation

Wiring

Figure 15b.

Fan wiring schematic.

Gas Control and Pilot Wiring

Honeywell (Q3450)
Pilot Assembly

Pilot Electrical

Harness Connector

Honeywell Gas

Control (SV9501M)

Gas Control

Connector

Fuse

Limit

Switch

Wall

Switch

Fan Plug

Receptacle

Junction Box

Junction Box Cover

White

Black

Green

40 VA

Transformer

115VAC

24VAC

Grnd Screw

Figure 14.

Wiring for the M38DV-PRC-I with Honeywell gas control

and pilot.

Figure 15a.

Fan wiring.

NOTE:

If any of the original wire supplied with the appli-
ance is replaced, it must be replaced with the same
type, or its equivalent.

Fan Wiring

The M38DV-PRC is equipped with 4 fans for circulating heat into the
living space. Installations in Canada must be in accordance with
CSA C22.1 Canadian Electrical Code Part 1 and/or Local Codes.
Installations in the USA must be in accordance with local codes

or, in the absence of local codes, with the National Electrical Code,
ANSI/NFPA 70-1987.

Fan Switch

M38DV-

Removing and Installing the In-

ner Doors

Door Removal

The inner (combustion) doors are located behind the outer decorative
doors. To remove the inner doors, simply unscrew the nine (9) ma-
chine screws on the top, bottom and side of the door.

(See figure 16).

Door Installation

To attach the inner doors, align the door with the screw holes and
re-fasten with all nine machine screws. Ensure that a good seal is
maintained.

Figure 16.

Removing inner doors.

115/1/60 Supply

G

L1 L2

Fan Switch

G

L2-WH

L1-BLK

Quick Connect

plug to motor

Fan Motors (4)

Advertising