background image

025-000570 Rev. X7

www.olsontech.com

24

CONNECTIONS & CONTROLS

POWER SUPPLY

J1

5-Pin DIN Connector to Power Units 1 through 5. Pinout is as follows;

Pin 1

Output DC Voltage (+13 or +17 V

DC

depending on the position of S1 left switch).

Pin 2

Ground

Pin 3

Ground

Pin 4

FAULT. If this input is LOW, D1 will light.

Pin 5

Causes D3-7 to light when pulled high.

Pin 6

22kHz flag. Power supply pulls this LOW if the 22kHz tone is enabled.

Pin 7

Ground

Pin 8

Ground

Pin 9

Ground

J6

AC Input. 90-250 V

AC

, 47-63 Hz. 2.5 Amp Slo-Blo, 5x20mm fuse.

D1

Power indicator. Green when normal.

D2

FAULT Indicator. If any module connector to J1 through J5 pulls pin 4 low, this will be
RED. Otherwise it will be dark.

D3-7 Indicates if a module is connected to this position.
S1-5 The left switch is used to select the LNB voltage (+13V or +17V). The right switch is

used to turn the 22kHz tone ON or OFF.