Ordering information – ONICON FB-3500 Series User Manual

Page 8

Advertising
background image

11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax (727) 442-5699 • [email protected]
FB-3500 Bi-Directional Insertion Electromagnetic Flow Meter Manual 05/14 - 0718-3

Page 8

1.5 ADDITIONAL HARDWARE THAT MAY BE REQUIRED

1.5.1 Grounding Rings

Grounding rings may be required whenever meters are installed in non-metallic or lined pipes.
Grounding rings placed before and after the meter eliminate electrical noise that will interfere
with the proper operation of the meter. ONICON provides grounding rings as an optional
accessory. Grounding ring dimensional information and part numbers are listed below. For proper
operation, grounding rings are required before and after the meter.

ORDERING INFORMATION

ANSI Class 150

316 Stainless Steel

Grounding Rings (pair)

Nominal

Size

ONICON Part

Number

1”

19265

1½”

19266

2”

19267

3”

19268

4”

19269

6”

19270

8”

19271

10”

19272

12”

19273

14”

19274

16”

19275

18”

19276

20”

19277

24”

19278

30”

19279

36”

19280

42”

19281

Grounding Ring Dimensions

Nominal Size

Bore

A

C

D

1”

1 - 1/16

2 - 5/8

4 - 9/16

1 - 15/16

1.5”

1 – 9/16

3 – 3/8

5 - 5/16

1 - 15/16

2”

2 – 1/16

4 – 1/8

6 - 1/16

1 - 15/16

3”

3 – 1/16

5 – 3/8

7 - 5/16

1 - 15/16

4”

4 – 1/16

6 – 7/8

8 - 13/16

1 - 15/16

6”

6

8 – 3/4

10 - 11/16

1 - 15/16

8”

8

11

12 - 15/16

1 - 15/16

10”

9 – 1/2

13 – 3/8

15 - 5/8

2 - 1/4

12”

11 – 9/16

16 – 1/8

18 - 9/16

2 - 7/16

14”

13 – 1/2

17 – 3/4

20 - 3/8

2 - 5/8

16”

15 – 1/4

20 – 1/4

22 - 7/8

2 - 5/8

18”

17 – 3/8

21 – 5/8

24 - 1/4

2 - 5/8

20”

19

23 - 7/8

26 - 11/16

2 - 13/16

24”

23

28 – 1/4

31 - 1/8

2 - 7/8

30”

29

34 – 3/4

38

3 - 1/2

36”

35

41 – 1/4

45 - 1/4

4

42”

41

48

52 - 1/2

4 - 1/2

D

C

3/8

5/8

Bore

A

1/4

1/8”

10 DIA

Gasket (4PL)

Grounding Ring (2PL)

Flow Direction

10 DIA

Typical Installation

Non-conductive Pipe

DIMENSIONS

Advertising
This manual is related to the following products: