F-3100 Flow Meter Manual 06/14 - 0670-7

Page

8

1.4 STANDARD FEATURES AND SPECIFICATIONS

A built-in user interface & display
A single 4 – 20 mA output for flow rate
Two programmable open collector pulse outputs. Outputs may be programmed to provide:

* an indication of flow direction

* a scaled pulse for totalizing flow

* a high resolution frequency output to drive peripheral devices

* an indication of an alarm condition

Empty pipe detector
Internal self-diagnostic functions & fault alarms

CALIBRATION

Flow meters are wet calibrated in a flow laboratory

against standards that are directly traceable to

government standards. A certificate of calibration

accompanies every meter.

ACCURACY

± 0.4% of reading from 3.3 to 33 ft/sec

± 0.8% of reading from 1 to 3.3 ft/sec

± 0.0075 ft/s at flows less than 1 ft/s

PROGRAMMING

Factory programmed for specific application

MEMORY

Nonvolatile memory retains all program parameters

and totalized values in the event of power loss.

DISPLAY

Alphanumeric LCD displays total flow, flow rate,

flow direction & alarm conditions

OUTPUT SIGNALS

Isolated 4 – 20 mA analog output for flow rate

Two programmable open collector pulse outputs

(configurable for frequency, pulse or directional

flow)

TEMPERATURE RANGE

Liquid temperature range:

Polypropylene liner: 32° to 140°F

Ebonite liner: 23° to 175°F

PTFE liner: -4° to 212° F (266° F with remote

electronics)

Ambient temperature range: 14° to 122°F

MAINTENANCE

Periodically inspect the power supply cables,

cable glands and the enclosure for signs of damage.

Inspect installation and mounting hardware for

loose connections.

MECHANICAL

Electronics Enclosure:

Standard: Nylon NEMA 4

Optional: Remote mount transmitter version,

maximum distance from the sensor is 65ft.

Outer Body Material:

Standard: Carbon Steel, Painted

Optional: 316 Stainless Steel

Flow Tube (Internal):

304 Stainless Steel

Connection Type:

Standard: ANSI 150 Class Flange

Optional: ANSI 300 Class Flange

Optional:

Wafer

Optional: Threaded Process Connection

ELECTRICAL

This equipment is intended for INSTALLATION

CATEGORY (OVERVOLTAGE CATEGORY) II

applications.

Input Power - Factory Selectable:

Standard - 90 to 265 VAC, 45 to 66 Hz, and 35 mA

maximum

Optional - 10 to 63 VDC, 15 to 45 VAC, 45 to

66 Hz and 300 mA maximum

Overcurrent Protective Device Ratings:

Supply mains overcurrent protective devices

with the following ratings:

• 120 VAC 50/60 Hz – 15 A

• 230 VAC 50 Hz – 6 A

Wiring:

Flow signals - Use 18-22 AWG shielded cable

Standard input power - Use a three wire service

with one wire a protective earth ground. The

installation must comply with all local, state

and federal building codes.

Optional input power - Use PVC jacketed copper

cable with a wire gauge suitable for the length

of run and required maximum current carrying

capacity. The installation must comply with all

local, state and federal building codes.

PRESSURE AND CONDUCTIVITY

Maximum Operating Pressure

(Exclusive of flange rating)

Ebonite:

1000PSI

Polypropylene:

230PSI

PTFE:

580PSI

Minimum Fluid Conductivity:

5

microsiemens/centimeter

Note: Specifications are subject to change wit

hout notice.