ONICON System-10 N2 User Manual

Page 11

Advertising
background image

11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax (727) 442-5699 • [email protected]
System-10-N2 BTU Meter Installation and Operation Guide 05/14 - 0655-5 / 18322

Page 11

STEP

ACTION

REACTION

COMMENT

4

Successively press the SCROLL
button to increment the number to
the desired value from 0-9.

The number increments
by one each time you
press the button.

The SCROLL button is on
the front panel.

5

Press the RESET button.

The second character
blinks.

The RESET button is on the
front panel.

6

Successively press the SCROLL
button to increment the number to
the desired value from 0-9.

The number increments
by one each time you
press the button.

The SCROLL button is on
the front panel.

7

Press the RESET button.

The third character
blinks.

The RESET button is on the
front panel

8

Successively press the SCROLL
button to increment the number to
the desired value from 0-9.

The number increments
by one each time you
press the button.

The SCROLL button is on
the front panel.

9

Once the correct address is
displayed, momentarily press the
PROGRAM pushbutton.

The FM LOCN page
appears with UNKNWN
defaulted as the current
location.

The PROGRAM button is on
the front panel.

10

Press the SCROLL button.

The setting will toggle
between UNKNOWN,
SUPPLY, and RETURN.

Refer to Section 4.5 of the
System-10 Installation and
Operation Guide if you with to
change settings.

11

Press the PROGRAM button.

The FRONT PANEL
RESET page appears.

It is not necessary to change
anything on this page.

12

Press the PROGRAM button.

The SAVE CHANGES
page appears.

The new device address
must be saved to take
effect.

13

Press the SCROLL button.

The N changes to Y on
the SAVE CHANGES
page.

The Y must be selected in
order for the new address to
take effect.

14

Press the PROGRAM button.

The new address is saved
and the display reverts to
the RUN mode.

15

Open the front panel and locate
the RESET switch. Press to reset
the System-10.

When polled, the
System-10 will
automatically begin to
communicate with the
network.

RESET is located along the
top of the heat computer
board. (See appendix page
A-1.)

Advertising