3.9 Installation of external rudder indicator

Onwa rudder indicator KRI-80 is supplied an option. Connect KRI-80 to

KAP-866 as follow:

Center and Range Calibration is needed on the KRI-80 after installation. Place

the rudder on midship position, adjust "Center" VR on KRI-80 to get "0"

degree on the meter. Place the rudder to 30 degree on either port or starboard,

adjust "Range" VR on KRI-80 to get "30" degree on the meter.

31

+

+

Canter

Range

5K control resistor
for dimmer control.

KAP-866 Autopilot