Soho Installation and Operation Manual

______________________________________________________________________________ 33

Clearances with ceiling (L) lowered to 72" (183 cm)

CLEARANCES

(SINGLE WALL PIPE)

CANADA

USA

A

15" (381 mm)

15" (381 mm)

B

16" (406 mm)

16" (406 mm)

C

10" (254 mm)

10" (254 mm)

D

18¾" (483 mm)

18¾" (483 mm)

E

24¾" (635 mm)

24¾" (635 mm)

F

19¾" (508 mm)

19¾" (508 mm)

K

48" (1219 mm)

48" (1219 mm)

L

72" (183 cm)

72" (183 cm)

CLEARANCES

(DOUBLE WALL PIPE)

CANADA

USA

A

12" (305 mm)

12" (305 mm)

B

16" (406 mm)

16" (406 mm)

C

7" (178 mm)

7" (178 mm)

D

15¾" (406 mm)

15¾" (406 mm)

E

24¾" (635 mm)

24¾" (635 mm)

F

16¾" (432 mm)

16¾" (432 mm)

K

48" (1219 mm)

48" (1219 mm)

L

72" (183 cm)

72" (183 cm)

Clearances for mobile homes

MOBILE HOME CLEARANCES (DOUBLE WALL PIPE)

CANADA

USA

A

12" (305 mm)**

12" (305 mm)**

B

16" (406 mm)

16" (406 mm)

C

7" (178 mm)

7" (178 mm)

D

15¾" (406 mm)**

15¾" (406 mm)**

E

24¾" (635 mm)

24¾" (635 mm)

F

16¾" (432 mm)

16¾" (432 mm)

K

48" (1219 mm)

48" (1219 mm)

L

84" (213 cm)

84" (213 cm)

**With the air mate option installed (AC01362 sold separately). Clearances A can be reduced to
10" (254 mm) and D to 13¾" (349 mm).