7.4.2

TABLE OF CLEARANCE REDUCTION PERCENTAGES

Type of shield

Clearances may be reduced by these

percentages

Sides

and rear %

Top %

(ceiling)

Can/USA

(%)

USA

min.

Can/USA

(%)

USA

min.

Sheet metal, a minimum of 24 gauge
(0.61 mm) in thickness , spaced out at
least

25 mm

(1 in)*

by

non-

combustible spacers

67

12 in

50

18 in

Ceramic tiles, or equivalent non-
combustible

material,

on

non-

combustible board spaced out at least
25 mm (1 in)* by non-combustible
spacers

50

18 in

33

24 in

Ceramic tiles, or equivalent non-
combustible

material,

on

non-

combustible board, with a minimum
of 24 gauge (0.61 mm) sheet metal
backing spaced out at least 25 mm
(1 in)* by non-combustible spacers

67

12 in

50

24 in

Brick, spaced out at least 25 mm
(1 in)* by non-combustible spacers

50

18 in

N/A

N/A

Brick, with a minimum of 24 gauge
(0.61 mm) sheet metal backing,
spaced out at least 25 mm (1 in)* by
non-combustible spacers

67

12 in

N/A

N/A


* In Canada this space can be 21 mm (7/8 in)