Paper, Power adaptor, Multiple interface issue – Posiflex AURA-6900 User Manual

Page 15

Advertising
background image

Part 15

Paper load method

Drop and use

Auto-cutter capability

Partial cut (1 point at center left)/full cut

Paper cutting method

Guillotine cutting

Manual cutter

Saw tooth blade

Dot Pitch

0.125 x 0.125 mm

Life span of print length

100 km

Life span of paper cutting

1 million or more

Input power type

DC

Input voltage

24 V + / - 5 %

Dimension (mm)

148 (W) x 205 (D) x 143 (H)

Weight

1.2 Kg net

PAPER

PAPER TYPE

THERMAL ROLL PAPER

Paper roll formation

External side is heat-sensitive side

Paper width

80 (or 58) + 0 / - 1 mm

Paper roll outer diameter

83 mm max.

Paper roll inner diameter

12 + 1 / - 0 mm

Paper thickness

60 ~ 80 um

POWER ADAPTOR

ITEM

REQUIREMENT

Input voltage

100 V AC ~ 240 V AC

Input frequency

50 ~ 60 HZ

Input current

1.8 A MAX. @ 115 V AC

Output voltage

+ 24 V DC

Output power

50 W

Static load

0 A ~ 2.08A

Output regulation

+ / - 5 %

EMI standards

VDE – A, FCC – A, VCCI – A

MULTIPLE INTERFACE ISSUE

For model PP-6900, there is only 1 connector for host connection through USB.
For PP-6900P, there are 2 connectors for host connection: USB and in addition
to Parallel port. For PP-6900S, there are 2 connectors for host connection:
USB Port and in addition to the Serial port. For PP-6900L, there are 2
connectors for host connection: USB and in addition to the LAN port. Please
always connect only one interface at a time. Simultaneous multiple host
connections could result in unexpected results!