Fig. 7 fig. 8 – Royal Cozyfires Super Hotbox Toaster MK4 - LPG User Manual

Page 8

Advertising
background image

8

HM83 010710

2.3 TECHNICAL

DATA

Super Hot Toaster Mk4

Fig.

7

Fig.

8







































2.4

INSTALLING THE APPLIANCE (Ventilation)


Ventilation required for this appliance must be fitted with the rules in force and checked regularly for obstructions:-

If the appliance is installed in GREAT BRITAIN, additional ventilation is NOT normally required.

If the appliance is installed in IRELAND, a minimal cross sectional area of 100cm

2

is required.


















Minimum

height of

opening is

590mm

Minimum

width of

opening is

410mm

Injector

044/341/196/048M

Gas Control

MP ESP 21531A

Main Burner

Aeromatix AC03/211657

Thermocouple

T100/927-400

Ignition

Single spark electrode direct to main burner

Gas Connection

8mm OD (restrictor elbow)

Gas Type

G31 PROPANE GAS

Maximum Heat Input

5.85kW (19,960 btu/hr) Gross

SPECIFICATIONS

Minimum Heat Input

3.6kW (12,283btu/hr)

Supply Setting Pressure

37mbar +/- 1mbar (Cold)

Flue Types

Class 1&2

505mm

600mm

Minimum

Depth of

opening is

220mm

Depth is

180mm w/out cable fixing

220mm with cable fixing

Advertising