Fig. 9, Fig. 10, Class 1 – Royal Cozyfires Super Hotbox Toaster MK4 - LPG User Manual

Page 9: Fig. 11, Class 2

Advertising
background image

9

HM83 010710

2.4.1

INSTALLING THE APPLIANCE (Flue)

Super Hot Toaster Mk4


Any permanent flue restriction must be removed and any variable dampers locked fully open or removed. If the flue has been used
previously for solid fuel, it must be swept PRIOR to installation. This appliance is suitable for installation into CLASS 1 & Class 2 flues.



















































410/490mm

555/590mm

Fig. 9

600mm

Class 1


A conventional brick or stone chimney with a minimum effective cross
section dimension of 225mm x 225mm.

A lined flue with a minimum diameter of 175mm having a chair brick and
throat lintel conforming to the current issue of BS 1251

(Fig 9).


The minimum distance required between the rear of the opening and the
front face of the surround is

220mm

I

f a chairbrick is fitted, it must be removed for this application together with

any infill or rubble. Any remedial work should be carried out including
levelling the base beneath the fire (Fig 10).

NOTE: A restrictor plate is supplied with the IFU kit. This restrictor plate
MUST ONLY BE USED ON THIS FLUE TYPE!

Hatched area must be non-combustible and

flat to ensure a seal around the appliance.

Fire

Min 25mm

Cavity between

rear of unit and

back of flue

Fig. 10

600mm

500mm

410mm

555mm

Hatched area must be non-

combustible and flat to ensure a

seal around the appliance.

Fig. 11

The area beneath the metal flue box

must be a non-combustible material

25mm thick.

Class 2

A twin walled metal flue box manufactured to the current
issue of BS 715 with a twin walled 125mm diameter flue
and a minimum effective height of 3 metres (Fig 11).

The flue box must be insulated by the installer, using a
minimum of 25mm thick insulation.

NOTE: The restrictor plate supplied in the IFU kit
MUST NOT BE USED ON THIS FLUE TYPE!

Care must be taken to

ensure that the flue

spigot from the

appliance does not

impede the flue outlet

from the metal box

500mm

Advertising