Installation: Water & Drain

Water Supply, all models: The recommended water
supply tubing is ¼ inch OD copper. Stainless steel
flex or reinforced PVC tube may also be used.
Install an easily accessible shut-off valve between
the supply and the unit. This shut-off valve should
not be installed behind the unit.

Note: Do not use self-piercing type valves.

1.

Remove the front service panel.

2.

Route the tubing through the right hole in the
back to the inlet water solenoid valve inlet.

3.

Install a compression fitting on the tubing and
connect to the inlet of the solenoid.

Drains

There are two types of ice machine models, one
that drains by gravity and one that has an internal
drain pump.

Drain Pump Model drain installation

1. Locate the coil of 3/8” ID plastic drain tubing
secured to the back of the unit.

2. Route the plastic drain tube from the back of the
unit to the drain connection point.

IMPORTANT NOTE: Often an air gap is required by
local codes between the ice maker drain tube and
the drain receptacle.

September 2011

Page 10

SCCG50 & SCCP50

Service Manual

Back View, Drain Pump Model

Water Inlet
Tube (field
supplied)

Drain Tube,
Route to
building drain

Screw

Securing

Front Service

Panel

Water Inlet
Connection,
located at the
FRONT of the
machine. Do
NOT connect
to tubing at
the back.