Specifications

This ice machine is designed to be used indoors, in
a controlled environment. It can be used in a wide
variety of environmental conditions, but there are
limits. Use outside of the listed limitations is misuse
and will void the warranty.

Air temperature limits:

The ice machine will operate adequately within the
limits, but functions best in temperatures between
70 and 80 degrees F.

Minimum – 50 degrees F. (10

o

C)

Maximum – 100 degrees F. (38

o

C)

Water temperature limits:

Minimum – 40 degrees F. (4.5

o

C)

Maximum – 100 degrees F. (38

o

C)

Water pressure limits:

Minimum – 20 psi (1.4 bar)

Maximum – 80 psi (5.5 bar)

Because the ice machine is making a food product,
the water supply to the ice machine must be
potable, or fit for human consumption.

Electrical

115 volt, 60 Hz. Plug into dedicated 15 amp
circuit.

Power consumption: 275 - 400 Watts. Varies
during Freeze and Harvest cycles.

Voltage limits:

Minimum - 104 volts

Maximum – 126 volts

Options:

Door Panel kits: Finished door panels are available
from Scotsman for attachment to the machine, or a
custom panel can be made.

Kit Number Panel Finish

Handle Finish

KDFW

White

White

KDFWS

White

Stainless Steel

KDFB

Black

Black

KDFBS

Black

Stainless Steel

KDFS

Stainless Steel

Stainless Steel

Kickplate Extension: In some situations the leg
levelers will be extended enough to become visible.
A kit to extend the kickplate over the legs is KKPF.

Cabinet Stability: In some free standing
installations it may be prudent to add a bracket that
secures the back of the cabinet to a wall. That kit
number is KATB.

Drain Conversion:

A gravity drain model can be converted to a drain
pump model by installing a drain pump kit. The
drain pump kit consists of a drain pump, wiring
harness and associated tubing. The kit number is
A39462-021.

Warranty Information

Warranty information is supplied separately from
this manual. Refer to it for coverage. In general, the
warranty covers defects in materials or
workmanship and does not cover corrections of
installation errors or maintenance.

July 2008

Page 2

SCCG50 & SCCP50

Service Manual

Models: There are six models, all air cooled:

SCCP50M-1WU – Pump model, white cabinet

SCCG50M-1WU – Gravity drain model, white cabinet

SCCP50M-1BU – Pump model, black cabinet

SCCG50M-1BU – Gravity drain model, black cabinet

SCCP50M-1SU – Pump model, stainless cabinet

SCCG50M-1SU – Gravity drain model, stainless cabinet