Sccg50 & sccp50 service manual – Scotsman SCCG50 User Manual

Page 23

Advertising
background image

Controller

The controller is located at the front of the unit,
under the top panel.

It is powered by a 12 volt transformer. It has 5
indicator lights:

Compressor - Light is ON if compressor is
powered

Water - Light is ON if inlet water solenoid
valve is powered

Hot Gas - Light is ON when Hot Gas Valve is
powered

Fan - Light is ON when Fan motor is
powered

Power - Light is ON when power is
connected to controller

Control Safeties:

No Water. If the Water Sensor cannot detect
water, and the inlet water solenoid valve has been
on for the maximum fill time, the controller will stop
all action and wait 20 minutes to re-try water fill.
During this time the Check Water light on the
control panel will be blinking,

Maximum Freeze Time. If the freeze cycle should
extend to 60 minutes, the controller will
automatically put the machine into a Harvest cycle.

Maximum Harvest Time. 6 minutes

Time between restarts. After the machine has
operated and then turned off, the controller will not
restart the machine for four minutes.

June 2008

Page 22

SCCG50 & SCCP50

Service Manual

Comp

Water

Hot Gas

Fan

Power

Evaporator

Thermistor

Water Sensor

Bin
Thermostat

Bin Light

Control Panel
Ribbon

High

Voltage

Connector

Power Supply
Connector

Advertising
This manual is related to the following products: