pk speciFicatiOns
Model
PH
Volts
Amps
Watts
Copper
Wire
Size*
NEMA
Receptacle
Fuse or
Breaker Size
KM1227PK
1
240
60
14400
4
Direct Wire
80
KM1227PK
1
208
69
14352
4
Direct Wire
90
KM1227PK
3
240
40
14300
6
Direct Wire
50
KM1227PK
3
208
46.7
14300
6
Direct Wire
60
KM1231PK
1
240
72
17280
2
Direct Wire
90
KM1231PK
1
208
80
16640
2
Direct Wire
100
KM1231PK
3
240
44.5
17300
6
Direct Wire
60
KM1231PK
3
208
51.5
17300
6
Direct Wire
65
KM1627PK-LF
1
240
68
16320
4
Direct Wire
85
KM1627PK-LF
1
208
69
14352
4
Direct Wire
90
KM1627PK-LF
3
240
46
16300
6
Direct Wire
60
KM1627PK-LF
3
208
47
14300
6
Direct Wire
60
KM1627PK
3
240
66
23600
4
Direct Wire
85
KM1627PK
3
208
76
23600
4
Direct Wire
95
*For each additional 50 feet use heavier wire, numerically two numbers lower—for example, instead of #10, use #8. If
you anticipate installing any larger kiln in the future, use the heavier wire. Electrical specifications listed above are suggested guidelines.
Local electrical codes may vary.