Connecting the SMTCP-R via TELNET

Commands may be sent transparently to the SM-RS232 via a TELNET connection to the

SMTCP-R. To use this function, use a telnet client such as Hyperterminal or PuTTY to connect

to the IP address of the SMTCP-R.

You will be prompted for a username and password - this will be the same as the login

information via HTTP. Once logged in, the SMTCP-R is ready to accept the standard RS-232

commands. For a list of the available commands, please see the user manual for the matrix

you are using.

Although the commands are not echoed to the client display, the commands are being issued

to the matrix. Should you need commands to be echoed, please see the instructions for your

TELNET client.

Upgrading the SMTCP-R

To updgrade the SMTCP-R with the latest firmware, contact your sales representative to obtain

the firmware upgrade file or visit the SMTCP-R product page at www.smartavi.com. The version

information is listed on the Main Menu.

Once you have the file, use an FTP client, preferably TFTP, to navigate to the IP

address of the SMTCP-R. To upload the file to the SMTCP-R, navigate to the /var/

directory, and upload the file firmware.img - IMPORTANT: the file MUST BE NAMED

firmware.img for the upgrade to work properly. Again, the full path MUST BE

/var/firmware.img.

Once the file has been copied, restart (power off and power on) the SMTCP-R. Once restarted the

firmware update will be installed. To verify the upgrade, see the version information listed on the

Main Menu.

Controlling the SM-RS232 with the SMTCP-R module (continued)