Troubleshooting – Tecfluid MT03F User Manual

Page 39

Advertising
background image

39

19

TROUBLESHOOTING

Problem

Probable cause

Solution

The flow rate is 0, the
accumulated total
counter and the totalizer
do not increase their
value

Incorrect input

Check that the input type
programmed in the menu matches
the connection made (see page
18)

Filter too restrictive

Check that the frequency of the
input signal is lower than that
indicated in the programmed filter
(see page 18)

Cable disconnected

Connect the cable between the
pulse transmitter and the MT03F

The flow rate displayed
is 0

The flow rate is smaller than
programmed as cut off

Decrease the value of the cut off
(see page 22)

The display is blank

Blown fuse

Change the fuse

The analog output gives
always 4 mA or 20 mA

Current output range not properly
programmed

Program the range properly (see
page 24)

The analog output gives
always 0 mA

Cable disconnected

Check the cable connection