TROUBLESHOOTING

SYMPTOM: When using 4 wires (R, G, W, Y),
the air conditioning or heating equipment
tries repeatedly to turn on, but cannot.
CAUSE: There is not enough power available
to "power share".
REMEDY: Connect a 250 ohm, 10 watt power
resistor at the furnace as shown below.

R

G

W

Y

C

TR300-10w

R

G

W

Y

C

TR300-10w

For Problem A/C

Note: 2 resistors may be used at the same time.
Not applicable with Heat Pump systems.

For Problem Heat

SYMPTOM: The air conditioning does not
attempt to turn on.
CAUSE: The compressor timer lockout may
prevent the air conditioner from
turning on for a period of time.
REMEDY: See page 13 of the Thermostat
Manual and configure step 8 to defeat
the 5-minute compressor lockout.

SYMPTOM: The display is blank.
CAUSE: Lack of proper power.
REMEDY: Make sure power is turned on to
the furnace and 24vac exists between
R & W. If C is used, 24vac between R & C.