Interface specifications – Westermo MRD-350 User Manual

Page 10

Advertising
background image

10

6623-2221

Interface specifications

Power
Rated voltage

12 – 48 VDC

Operating voltage

10 – 60 VDC

Rated current (max)

370 mA @ 12 VDC

Start-up current (max)

1000 mA @ 12 VDC

Rated frequency

DC

Consumption guidance*

Voltage

Mode

Consumption

12 VDC

GPRS

Idle

165 mA

24 VDC

GPRS

Idle

90 mA

48 VDC

GPRS

Idle

55 mA

12 VDC

GPRS

Send

240 mA

24 VDC

GPRS

Send

130 mA

48 VDC

GPRS

Send

75 mA

12 VDC

3G

Idle

225 mA

24 VDC

3G

Idle

120 mA

48 VDC

3G

Idle

70 mA

12 VDC

3G

Send

275 mA

24 VDC

3G

Send

155 mA

48 VDC

3G

Send

80 mA

12 VDC

3G

Send&Receive

330 mA

* For example purpose only. Hard to predict exact values since there are a lot of factors that affect the power

consumption, such as signal strength. Example measurement was carried out in-doors in a 25ºC room with

"normal" signal strength.

RS-232
Electrical specification

EIA RS-232

Data rate

300 bit/s – 115.2 kbit/s

Data format

7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits

Protocol

Transparent, optimised by packing algorithm

Circuit type

SELV

Transmission range

15 m / 49 ft

Connection

9 pin D-sub female

Shielded cable

Not required

Conductive housing

Yes

Number of ports

1