Current Drain

120

µ

A

10mA + analogue loop
current

“Sleep” mode

Operating mode

Analogue loop supply

Included

10 - 12V DC 50mA

Low Battery voltage status

Monitored

Can be transmitted to remote
modules

Radio Transmitter

Frequency

405 - 490 Mhz

12.5/20 kHz channel spacing

Synthesised Transmitter -
Frequency configurable range

10MHz

Direct frequency modulation

Transmit power

10, 100, 500mW

250mW max. with internal
batteries (500mW with 3dB
antenna), 100mW max with 2 x AA
internal battery supply

Spurious emissions

TX - <-37 dBm

Frequency Stability

+/- 1.0 kHz

Expected line-of-sight range

2 km @ 10mW EIRP
5 km @ 100mW EIRP
10 km @ 500 mW EIRP

Range may be extended by using up
to 5 intermediate 105U modules as
repeaters,

Antenna Connector

Female BNC coaxial

Serial Ports

RS232 Port

DB9 female DCE

4800 baud, no parity, 8 data bits, 1
stop bit

Data transmission
- digital inputs

On change-of-state + after
update period elapsed

Update time configurable 10 secs -
5 days. Separate, faster update time
may be configured when input is
ON

Data transmission
- pulse inputs

Transmitted as pulse count

Transmitted when count change
exceeds configured amount, or on
time elapsed since last transmission
(configurable 10 secs - 5 days)

2 pulse inputs may be
configured to a single count

Suitable for quadrature or
incremental shaft encoders.