Technical specifications, 2 technical specifications – AEC VacTrac Series Conveying Systems User Manual

Page 108

Advertising
background image

7-2 Technical

Specifications

The following design information is provided for your reference:

1. No modifications are allowed to this equipment that could alter the CE compliance

2. Ambient temperature: 40 degrees Celsius – Maximum (104 degrees Fahrenheit)

3. Humidity range: 50% relative humidity

4. Altitude:

Sea level

5. Environment:

Clean, dust-free and non-explosive

6. Radiation:

None

7. Vibration:

Minimal, i.e. machine mounting

8. Allowable voltage fluctuation:

+/- 10%

9. Allowable frequency fluctuation:

Continuous

+/- 1%

Intermittent

+/-

2%

10. Nominal supply voltage:

460/3/60 (Verify on serial number tag)

11. Earth ground type:

TN (system has one point directly earthed through a

protective conductor)

12. Power supply should include a ground connection.

13. Over-current protection is supplied in the conveying system, but additional protection

should be supplied by the user.

14. The door-mounted disconnect serves as the electrical disconnect device.

15. Conveying system is not equipped with local lighting.

16. Functional identification

17. Conveying system is equipped with a CE mark

18. Conveying system is supplied with an operating manual in the language of the

destination country.

19. Cable support may be required for power cord, depending on final installation.

20. No one is required to be in the interior of the electrical enclosure during the normal operation

of the unit. Only skilled electricians should be inside the enclosure for maintenance.

21. Doors can be opened with a screwdriver, but no keys are required.

22. Two-hand control is not required or provided.

23. All components should be moved around and set in a place with a lift truck or equivalent.

24. There are no frequent repetitive cycles that require manual control

repetitive

functions are automatic while the conveying system is operating.

25. An inspection report detailing the functional test is included with the conveying system.

26. The machine is not equipped with cableless controls.

27. Color-coded (harmonized) power cord is sufficient for proper installation.

Conveying System Mechanical Components Chapter 7: Appendix

107 of 136

Advertising