Sub panel layout and connection diagram, Power wiring with disconnect switch – AEC VacTrac Series Conveying Systems User Manual

Page 80

Advertising
background image

Figure 45: Typical VTTV Series Junction Box with Fused Disconnect Wiring Diagram

POWER WIRING WITH DISCONNECT SWITCH

3 PHASE / 4 WIRE SERVICE

L1

L3

L2

95

CONTROL WIRING

BE PROVIDED BY CUSTOMER

JUNCTION BOX ON VACUUM PUMP

115V AC CONTROL VOLTAGE

FROM CONTROLLER OUTPUT

SUB PANEL LAYOUT AND CONNECTION DIAGRAM

FROM DISC-1

(MTR)

TO MOTOR

ON MOTOR STARTER (M)

(115V AC)

OL

2

T1

1

L1

3

L2

5

L3

13

A1

A2

T2
4

T3

6

14

A2

95

96 97

98

TEST

TRIPPED

RESET

2

T

1

T

2

T

3

4

6

J1

T2

T1

T3

M

ON OVERLOAD (OL)

TO TERMINAL #96

TO SOL

TO L1, L2 AND L3

L1

FROM L1, L2 AND L3

AT BOTTOM OF

DISCONNECT SWITCH

(DISC)

(NEUTRAL)

L1

L2 L3

GRD

SOLENOID

FOR VACUUM/VENT

FROM CONTROLLER OUTPUT

L1

FROM CONTROLLER OUTPUT

FROM CONTROLLER OUTPUT
FOR PUMP MOTOR STARTER

SOLENOID

FOR PUMP VACUUM/VENT

DISC

L2

L3

DISC-2

DISC-1

DISC

96

0L

FOR MOTOR STARTER

L2

L3

(FROM DISC-2)

L3

L2

L1

FU

FU

FU

DISC

VACUUM PUMP

MOTOR STARTER

VACUUM/VENT

SOLENOID ON PUMP

SOL

OPTIONAL

M

J1

A2

A1

(NEUTRAL)

T3

T2

M

OL

T1

2 H.P. PUMP

MTR

95

FROM CONTROLLER OUTPUT

FROM CONTROLLER OUTPUT
FOR PUMP MOTOR STARTER

SOLENOID

FOR PUMP VACUUM/VENT

0L

96

VACUUM/VENT

SOLENOID ON PUMP

VACUUM PUMP
MOTOR STARTER

(+24V DC)

M

J1

SOL

A2

A1

OPTIONAL

DISC-1

CONTROL WIRING

JUNCTION BOX ON VACUUM PUMP

24V DC CONTROL VOLTAGE

FROM CONTROLLER OUTPUT FOR

VACUUM/VENT SOLENOID

(MTR)

TO MOTOR

T2

T1

T3

ON MOTOR STARTER (M)

ON MOTOR STARTER

TO L1, L2 AND L3

FROM CONTROLLER OUTPUT

FOR PUMP MOTOR STARTER

FROM L1, L2 AND L3

AT BOTTOM OF

DISCONNECT SWITCH

(DISC)

(+24VDC)

OL

2

T1

1

L1

3

L2

5

L3

13

A1

A2

T2
4

T3

6

14

A2

95

96 97

98

TEST

TRIPPED

RESET

2

T

1

T

2

T

3

4

6

J1

M

L1

L2 L3

MOTOR STARTER (M)

(+24V DC) ON

TO TERMINAL A1

L1

L1

(FROM DISC-1)

GRD

DISC

L2

L3

L2

L3

SUB PANEL LAYOUT AND CONNECTION DIAGRAM

(24V DC)

TO TERMINAL A1 (NEUTRAL)

ON MOTOR STARTER (M)

ON MOTOR STARTER (M)

TO TERMINAL A1 (+24VDC)

Note: For XPD and XPC Series junction box wiring diagrams, consult the wiring
diagram that was shipped with your specific piece of equipment. Consult your
information packet.

Conveying System Mechanical Components Chapter 3: Installation

79 of 136

Advertising